Technical Information:... |
||
![]() |
||
| StockStop Trackway Grid | ||
|
Features a pair of concrete end-base sections plus one or more mid-base sections which can be combined to cover any pit width from 3000 mm in increments of 760mm1. |
||
| End Sections: 482mm x 3120mm x 450mm ( length x width x depth) | ||
| Mid Sections: 760mm x 3120mm x 450mm ( length x width x depth) | ||
|
The base sections are made from high strength reinforced concrete - C50 mix to BS 8500. |
||
| The base sections include fixing points for the grid and side fences plus hedgehog escape/drainage ducts. | ||
|
Features a heavy duty grid, galvanised to BS 1461. |
||
|
Design is compliant with BS 4008 1991. |
(what is BS4008?) | |
|
80kN/m HA loading to BD37/ 88. No HB loading:.... |
(what is HA/HB loading?) | |
| ( Up to and including 44 tonne HGV's, eg normal farm, estate and forestry traffic. ) | (HGV limits) | |
| Optional side fences - also galvanised to BS 14612. | ||
| Hedgehog friendly design | ||
| - hedgehogs can escape away from the road surface via the ducts in the side walls. | Hedgehog Ramps | |
| The base sections require a firm base consistent with the existing track or CBR test. | ||
| 1 | Pit width refers to the grid width. A 3000mm wide grid for example, uses 2 end base sections and 3 mid base sections. The overall base width equals grid width plus 245mm. | |
| 2 | To comply with BS4008, side fencing should be extended beyond the grid. | |
For Technical Info on our other models:.... Driveway Grid, Highway Grid